Features
Characteristic:
·LCDI can cut the load circuit timely, make the leakage current in the cut-circuit will
not Beyond 5mA.
·When the leakage fault between shield wire and L-wire or N-wire happened, LCDI can cut
the Circuit before 8.5 cycles disengaging in 0.5 second.
·L-G 、N-G and load-end can sustain 1240V endurance test in a minute.
·120V LCDI accommodation:AC102V-AC132V,240V LCDI Accommodation:AC204V-AC264V.
·Surge-proof function: can sustain 4KV/2KA combined-surge attack, the surge is applied
at Phase angels of 90 and 270, and five applications are at positive, five applications
are At negative. Total surge cycles are 20.
·Over-load function: can sustain 50 over-load tests, whose test current is 6 times of
the Rated current. in 0.5 second
Specifications
·leakage current detection interrupter
·meets UL 1699 requirement
·meets UL 498& UL 484 requirement
·120V/240V 14AWG around wire
disengaging in 0.5 second